Some assemblies may require additional equipment. Please check the "More Information" column for details.

20 products found.

ModelApplicationDuct DirectionGrillControlsFunctionVoltageControl VoltageHeat Strip Ready 
8330-763DuctedLateral DuctStandard GrillManualAC120VAC/60HzN/A More Information

The Coleman-Mach Lateral Ducted ceiling assembly with manual controls is ideal in applications where there is no 12VDC available, or no ideal locations for a wall thermostat. 

 

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

8330A733DuctedLateral DuctStandard GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Standard lateral ducted ceiling assembly for use with 12VDC wall thermostat

 

Recommended Thermostat:

Analog = 7330G3351

Digital = 8330-3362

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

 

8330A743DuctedLateral DuctStandard GrillWall ThermostatAC120VAC/60Hz24VAC More Information

Standard lateral ducted ceiling assembly for use with 24VAC wall thermostat

 

Recommended Thermostat:

Analog = 7330B3441

Digital = 8330A3241

(Note: The control box with this ceiling assembly supplies 24VAC for the thermostat)

 

8330D735DuctedLateral DuctStandard GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Standard lateral ducted heat ready ceiling assembly for use with 12VDC wall thermostat

 

Recommended Thermostat:

Digital = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

8430A6301DuctedCenter DuctChill GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

For this application you will also need:

Control kit = 8330-752

Thermostat = 7330G3351

Alternate Digital thermostat = 8330-3362

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

 

 

                                                                                  

 

8430A6301DuctedCenter DuctChill GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

For this application you will also need:

Control kit = 9330C755

Thermostat = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

8430A6301DuctedCenter DuctChill GrillWall ThermostatHeat Pump120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

For this application you will also need:

Control kit = 9530A751

Thermostat = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

8430A6301DuctedCenter DuctChill GrillWall ThermostatAC120VAC/60Hz24VAC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

For this application you will also need:

Control kit = 8530-750

Analog Thermostat = 7330B3441

or

Digital Thermostat = 8330A3241

 

8430A633DuctedLateral DuctChill GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

Recommended Thermostat:

Non Digital = 7330G3351

Digital = 8330-3362

 

8430A635DuctedLateral DuctChill GrillWall ThermostatAC120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

Recommended Thermostat:

8530A3451

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

8530D735DuctedLateral DuctStandard GrillWall ThermostatHeat Pump120VAC/60Hz12VDC More Information

Standard lateral ducted Heat Pump ceiling assembly for use with 12VDC wall thermostat

 

Recommended Thermostat:

Digital = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

 

8630A635DuctedLateral DuctChill GrillWall ThermostatHeat Pump120VAC/60Hz12VDC More Information

Exclusive DirectFlow Louver System provides cool air where you need it for personalized comfort in any RV!

  • Open the specially designed Louvers to channel cool air straight down into the cabin.
  • Close the louvers to divert cool air through your existing duct system.
  • Exclusive EZReach Filter System provides quick access to the washable air filter.
  • Slender profile provides plenty of overhead clearance.

Recommended Thermostat:

8530A3451

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

9430-4552Non DuctedN/AN/AWall ThermostatAC120VAC/60Hz12VDC More Information

Myth:  “You cannot run your Coleman AC with a wall thermostat in a non-ducted application.”

INCORRECT!

For the convenience of a wall thermostat, in a non-ducted application; you only need the 9330F4552 non-ducted ceiling assembly along with the recommended control components for your particular application (listed below)

For this application you will also need:

Control Kit = 9330C755

Thermostat = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

9430-4552Non DuctedN/AN/AWall ThermostatAC120VAC/60Hz12VDC More Information

Myth:  “You cannot run your Coleman AC with a wall thermostat in a non-ducted application.”

INCORRECT!

For the convenience of a wall thermostat, in a non-ducted application; you only need the 9330F4552 non-ducted ceiling assembly along with the recommended control components for your particular application (listed below)

For this application you will also need:

Control Kit = 8330-752

Analog Thermostat = 7330G3351

or

Digital Thermostat = 8330-3362

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

 

9430-4552Non DuctedN/AN/AWall ThermostatHeat Pump120VAC/60Hz12VDC More Information

Myth:  “You cannot run your Coleman AC with a wall thermostat in a non-ducted application.”

INCORRECT!

For the convenience of a wall thermostat, in a non-ducted application; you only need the 9330F4552 non-ducted ceiling assembly along with the recommended control components for your particular application (listed below)

For this application you will also need:

Control Kit = 9530A751

Thermostat = 8530A3451

(Note:  The control box does not provide 12VDC for the thermostat, this will need to be supplied by the application.)

Add On Heat Kit:

For 47000 series use part number 47233-4551

For all but 47000 series use part number 9233A4551

 

9430-4552Non DuctedN/AN/AWall ThermostatAC120VAC/60Hz24VAC More Information

Myth:  “You cannot run your Coleman AC with a wall thermostat in a non-ducted application.”

INCORRECT!

For the convenience of a wall thermostat, in a non-ducted application; you only need the 9330F4552 non-ducted ceiling assembly along with the recommended control components for your particular application (listed below)

For this application you will also need:

Control kit = 8530-750

Analog Thermostat = 7330B3441

or

Digital Thermostat = 8330A3241

 

9430D715Non DuctedN/AN/AManualAC120VAC/60HzN/A More Information
                                                                                                                      

 

9430D715Non DuctedN/AN/AManualAC120VAC/60HzN/A More Information
                                                                                                                      

 

9470F715Non DuctedN/AN/AManualAC240VAC/50HzN/A More Information

Control knobs mounted on end for best visibility and ease of operation.  Designed with a special contour to fit snugly against convex vehicle ceilings.  Only two inches thick and weighs just over six pounds.  Filter replacement is convenient and easy to perform.

Add On Heat Kit:

For 47000 series use part number 47330-4551 (1050W)

                                     or          47333-4551 (1600W)

For all but 47000 series use part number 9333-4551

 

 

 

9630-715Non DuctedN/AN/AManualHeat Pump120VAC/60HzN/A More Information